Menzolit SMC and BMC for rail applications PDF Print E-mail
Rail applications usually require the stiffness and surface performance levels as other applications do. However beyond these well known properties of SMC and BMC a major demand for mass transit are the fire, smoke and toxicity advantages of materials used outside and especially inside the train.

Fire and smoke standards for rail / passenger – mass transit

There are still many national standards in place, the struggle for a European one is still not established as a common standard, only as Technical Specification.

France, AFNOR NF F 16-101

The AFNOR NF F 16-101 contains within others.:
_ NF X 70-100 ( Smoke toxicity )
_ NF X 10-702 ( Smoke density )
_ NF P 92-504 ( Spread of flame )

Italy, UNIFER E 10.02.977

The UNIFER E 10.02.977 contains f.e.:
_ UNI 9174
_ UNI 8456
_ AFNOR NF F 16-101

Germany DIN 5510

The norm DIN 5510 part 2 contains the following tests:

Flammability according to E DIN 54 837
Class
Limits
menzolit SMC 0190
S 2
destroyed length <  30 cm, Extinguishing allowed
ok
S 3
destroyed length <  25 cm, Time of afterburning < 100 s, no speciman > 120 s
ok
S 4 destroyed length <  20 cm, Time of afterburning < 10 s ok
S 5destroyed length 0 cm -

Smoke development according to E DIN 54 837
Class
Limits
menzolit SMC 0190
SR  1
Integral of attenuation of light < 100 %
-
SR  2
Integral of attenuation of light <  50 % ok

Drippability according to E DIN 54 837
Class
Limits
menzolit SMC 0190
ST 1
drops / drops off burning
-
ST  2
does not drop / does not drop off burning
ok

Great Britain BS 6853

Test
Parameter Limit menzolit SMC 2400

 
Cat.1 a
Cat. 1b
Cat. 2
classification
Value
Smoke Density
BS 6853:1999 annex D
clause D.8.4
A on
A off
2,6
3,9
4,2
6,3
9,4
14
Cat. 1b
3,98
4,54
Smoke toxicity
BS 6853:1999 annex B
(large Specimen)
R
1,0
1,6
3,6
Cat. 1a
0,7
Fire propagation
BS 476-6
i
l
6
12
6
12
no criteria
no criteria
Cat. 1a
0,23
10,76
Spread of flame
BS 476-7
class
1
1
1
Cat. 1a
class 1

Europe, TS EN 45545

Test
limit for HL4 menzolit SMC 2400



classification
value
Spread of flame nach ISO 5658-2 CFE
> 37,8 kW/m2
ok   HL 4
40,6
Smoke density nach ISO 5659-2 Ds(4min)
VOF4
< 150
< 300
ok   HL 4 92,1
119,93
Smoke Toxicity nach ISO 5659 FED(t)=1
CTI < 1, t > 600 s
ok   HL 4 0,137 (t=1200s)
Heat release rate nach ISO 5660-1
MAHRE
< 60 kW/m2
ok   HL 4 50,2

USA, NFPA 130

Zhe NFPA 130 contains:
_Flame Spread TEst by ASTM E 162-95
_Smoke Density Test by ASTM E 662

Productlist

Product code Description


BMC 0190 General purpose BMC for electrical applications. Fire retardancy UL 94, V-0 (3 mm).
SMC 0190 General purpose SMC for electrical applications. Fire retardancy UL 94, V-0 (3 mm). Yellow card available.
SMC 2400 This is a newly developed product of very low smoke density and non toxic smoke. The product is qualified according to British standard BS 6853 level 1b and pr EN 45545.